BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//ChamberMaster//Event Calendar 2.0//EN
METHOD:PUBLISH
X-PUBLISHED-TTL:P3D
REFRESH-INTERVAL:P3D
CALSCALE:GREGORIAN
BEGIN:VEVENT
DTSTART:20200326T130000Z
DTEND:20200326T220000Z
X-MICROSOFT-CDO-ALLDAYEVENT:FALSE
SUMMARY:Vapor Distribution Refresher-Rochester
DESCRIPTION:This class combines the best of the very popular Propane System Restart with the Exterior Vapor Distribution Refresher. This class will review all the appropriate inspections\, tests and procedures necessary to put a vapor propane system back into operation after an interruption of service\, alteration of the system\, out of gas situation or after a 'leak' or 'I smell gas' type of service call. In addition\, the class will review the tasks and procedures required in selecting\, delivering and installing propane containers\, piping systems and regulators for customers. The class will cover the following: \n\n  A brief review of the exterior propane system & 2 stage systems\; 2# systems \n\n  Conducting interior site assessment of piping and appliance \n\n  Review and inspection of venting and ventilation \n\n  Procedures for leak checking a system \n\n  Purging air from gas piping systems & Placing appliances into operation \n\n  Selecting\, loading and transporting legal containers \n\n  Underground tank installation and cathodic protection \n\n  Installing containers and lines\, \n\n  Proper line sizing and line material selection \n\n  Selecting and installing regulators and meters \n\n  Conducting performance tests for installed regulators (flow and lock
X-ALT-DESC;FMTTYPE=text/html:<p><span style="font-size:9pt">This class combines the best of the very popular Propane System Restart with the Exterior Vapor Distribution Refresher. This class will review all the appropriate inspections\, tests and procedures necessary to put a vapor propane system back into operation after an interruption of service\, alteration of the system\, out of gas situation or after a &lsquo\;leak&rsquo\; or &lsquo\;I smell gas&rsquo\; type of service call. In addition\, the class will review the tasks and procedures required in selecting\, delivering and installing propane containers\, piping systems and regulators for customers. The class will cover the following: </span></p>\n\n<p><span style="font-size:9pt">&bull\; A brief review of the exterior propane system &amp\; 2 stage systems\; 2# systems </span></p>\n\n<p><span style="font-size:9pt">&bull\; Conducting interior site assessment of piping and appliance </span></p>\n\n<p><span style="font-size:9pt">&bull\; Review and inspection of venting and ventilation </span></p>\n\n<p><span style="font-size:9pt">&bull\; Procedures for leak checking a system </span></p>\n\n<p><span style="font-size:9pt">&bull\; Purging air from gas piping systems &amp\; Placing appliances into operation </span></p>\n\n<p><span style="font-size:9pt">&bull\; Selecting\, loading and transporting legal containers </span></p>\n\n<p><span style="font-size:9pt">&bull\; Underground tank installation and cathodic protection </span></p>\n\n<p><span style="font-size:9pt">&bull\; Installing containers and lines\, </span></p>\n\n<p><span style="font-size:9pt">&bull\; Proper line sizing and line material selection </span></p>\n\n<p><span style="font-size:9pt">&bull\; Selecting and installing regulators and meters </span></p>\n\n<p><span style="font-size:9pt">&bull\; Conducting performance tests for installed regulators (flow and lock</span></p>\n
LOCATION:Wood Lake Meeting Center 210 Wood Lake Dr. SE Rochester\, MN 55904
UID:e.9523.365
SEQUENCE:3
DTSTAMP:20260912T051051Z
URL:https://discoverpropanemn.com/events/details/vapor-distribution-refresher-rochester-365
END:VEVENT

END:VCALENDAR
